Shanghai Orsin Medical Technology Co., Ltd.
Shanghai Orsin Medical Technology Co., Ltd.
products
Home /

products

GEL Clot Yellow Top Vacutainer High Throughput Testing Clot Activator Gel

Product Details

Place of Origin: China

Brand Name: Orsin

Certification: ISO 13485

Model Number: Gel Clot ActivatoR

Payment & Shipping Terms

Minimum Order Quantity: 100/pcs

Price: Negotiation

Delivery Time: 1-4 weeks

Payment Terms: L/C,D/A,D/P,T/T,Western Union

Supply Ability: 20million/pcs/moth

Get Best Price
Chat Now
Specifications
Highlight:

GEL Clot yellow top vacutainer

,

customized yellow top vacutainer

,

high throughput clot activator gel

Features:
Ultra-Sensitive Detection
Cloro:
Can Be Customized
Company Visits:
Welcome To Visit Company And Factory
Tube Cap Type:
Screw Cap
Tube Stopper:
Rubber
Anticoagulant Properties:
Excellent
Feature:
Pure Serum Isolation
Platelet Activity:
Stability Upheld
Packing:
100pcs/box, 1000pcs/carton
Logo Printing:
Available For Big Orders (>30000 PCS)
Storage:
Store At Room Temperature
Tube Label:
Graduated Scale In Ml
Material Types:
PET/Glass
Anticoagulant Forms:
Sodium Or Lithium Salt
Closure Type:
Rubber Stopper
Features:
Ultra-Sensitive Detection
Cloro:
Can Be Customized
Company Visits:
Welcome To Visit Company And Factory
Tube Cap Type:
Screw Cap
Tube Stopper:
Rubber
Anticoagulant Properties:
Excellent
Feature:
Pure Serum Isolation
Platelet Activity:
Stability Upheld
Packing:
100pcs/box, 1000pcs/carton
Logo Printing:
Available For Big Orders (>30000 PCS)
Storage:
Store At Room Temperature
Tube Label:
Graduated Scale In Ml
Material Types:
PET/Glass
Anticoagulant Forms:
Sodium Or Lithium Salt
Closure Type:
Rubber Stopper
Description
GEL Clot Yellow Top Vacutainer High Throughput Testing Clot Activator Gel
GEL Clot Yellow Top Vacutainer High Throughput Testing Clot Activator Gel
Product Specifications
Attribute Value
Cloro Can be customized
Company Visits Welcome to visit company and factory
Tube Cap Type Screw Cap
Tube Stopper Rubber
Anticoagulant Properties Excellent
Feature Pure serum isolation
Platelet Activity Stability upheld
Packing 100pcs/box, 1000pcs/carton
Logo Printing Available for big orders (>30000 PCS)
Storage Store at room temperature
Tube Label Graduated Scale in ml
Features Ultra-Sensitive Detection
Material Types PET/Glass
Anticoagulant Forms Sodium or lithium salt
Closure Type Rubber Stopper
Yellow Cap GEL & Clot Vacuum Blood Collection Tube for High-Throughput Testing
Serum Separator Tubes with Clot Activator

Serum separator tubes with clot activator (commonly known as "yellow-top tubes") are vacuum blood collection tubes designed for rapid serum preparation. Pre-filled with inert separator gel and high-activity clot activator, these tubes accelerate clotting post-collection. During centrifugation, the gel forms a stable barrier to completely separate serum from blood cells, ensuring sample purity and stability.

Application Scenarios
  • Biochemical Testing: Liver/kidney function, lipids, glucose, and other routine biochemistry
  • Immunoassays: Hormones, tumor markers, infectious disease antibodies (e.g., HBV, HIV)
  • Therapeutic Drug Monitoring: Blood drug concentration analysis (e.g., cyclosporine, valproic acid)
  • Blood Bank Applications: Serum preparation for cross-matching
  • Automated Platforms: Compatible with high-throughput laboratory automation systems
Product Highlights
Feature Description
Rapid Clotting Clot activator ensures full coagulation within 15-30 minutes, reducing preprocessing time
High-Purity Serum Gel density (1.04-1.05 g/mL) forms a stable barrier during centrifugation, preventing cellular contamination
Enhanced Stability Blocks cellular metabolite release; serum remains stable for 48 hours at 2-8°C
Broad Compatibility Suitable for mainstream biochemistry/immunoassay analyzers; eliminates fibrin interference
Cross-Contamination Prevention Silicone-coated interior minimizes cell adhesion and sample residue
Usage Precautions
  • Collection Protocol:
    • Gently invert tube 5-8 times immediately after draw to mix clot activator with blood
    • Avoid vigorous shaking to prevent hemolysis or gel barrier damage
  • Centrifugation:
    • Centrifuge after complete clotting (1500-2000 ×g, 10-15 min) at 18-25°C
    • Low-temperature centrifugation may impair gel solidification
  • Sample Handling:
    • Transfer serum within 2 hours post-centrifugation to avoid prolonged gel contact
    • For insufficient serum (e.g., lipemic samples), perform secondary centrifugation without disrupting the gel barrier
Troubleshooting Guide
Issue Possible Cause Solution
Cloudy Serum/Gel Mixing Inadequate centrifugal force/time Recentrifuge (≥2000 ×g, 15 min)
Delayed Clotting Incomplete mixing or anticoagulant carryover Ensure proper mixing; change draw site
Gel Barrier Breakage Low centrifugation temperature or vibration Centrifuge at room temp; avoid transport shock
Hemolysis Difficult draw or excessive mixing force Use appropriate needle size; invert gently
Basic Parameters
Parameter Specifications
Common Sizes 1-10mL (adult/pediatric use)
Gel Density 1.04-1.05 g/mL (precision separation)
Vacuum Accuracy Within ±10%
These tubes integrate clot activation and gel separation technologies to enhance serum preparation efficiency and quality, reduce manual processing time, and minimize testing errors caused by improper sample handling. They are essential tools for standardized, high-throughput testing in modern laboratories.
Send your inquiry
Please send us your request and we will reply to you as soon as possible.
Send